UPS-PC-652A

Question
UPS switches off automatically after a very short time, but the battery indicator still shows (almost) full battery.
Answer
Every UPS has a certain maximum power output (W), but also a minimum required load. In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work. Otherwise it will shut itself down automatically as a safety measure to preserve the batteries. Also when the connected load is higher than the maximum capacity of the UPS, the device will shut down.

UPS-PC-1202AP

Question
UPS switches off automatically after a very short time, but the battery indicator still shows (almost) full battery.
Answer
Every UPS has a certain maximum power output (W), but also a minimum required load. In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work. Otherwise it will shut itself down automatically as a safety measure to preserve the batteries. Also when the connected load is higher than the maximum capacity of the UPS, the device will shut down.

UPS-PC-850AP

Question
UPS switches off automatically after a very short time, but the battery indicator still shows (almost) full battery.
Answer
Every UPS has a certain maximum power output (W), but also a minimum required load. In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work. Otherwise it will shut itself down automatically as a safety measure to preserve the batteries. Also when the connected load is higher than the maximum capacity of the UPS, the device will shut down. Question
UPS switches off automatically after a very short time, but the battery indicator still shows (almost) full battery.
Answer
Every UPS has a certain maximum power output (W), but also a minimum required load. In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work. Otherwise it will shut itself down automatically as a safety measure to preserve the batteries. Also when the connected load is higher than the maximum capacity of the UPS, the device will shut down.

BC-USB-02

Question
USB output port for practical powerbank function (5V / 2A) But no info with batteries type supports 5V/2A?
Answer
This charger can charging powerbank,need put into 3.7V lithium-ion rechargable batteries with 5V output.(put into li-ion rechargeable battery, activate USB output,if there is no load,it will into automatic sleep mode) Question
This charger supports 18650 Soshine LiFePO4 1800 mAh 3.2V protected batteries?
Answer
This charger not support with 3.2V LiFePO4 battery,only can use for 3.7V lithium-ion rechargeable battery,1.2V NiMH rechargeable battery and 1.2V NiCd rechargeable battery. Question
What fast recharge protocols does USB-C support for charging the batteries themselves?
Answer
Input for Type C:5V/2A 9V/2A 12V/1.5V Output for fast charging: 4.2V 0.75A*4 1.5A*2 3.0A*1,need put batteries in the first slot or in the fourth slot Question
What type of batteries does the 5V/2A USB PowerBank need Ni-MH / Ni-CD / Li-ion (form-factor)?
Answer
3.7V Li-ion recharegable batteries

EG-UPSO-1000

Question
How to activate the ECO mode? Where is the ECO function?
Answer
You can set it via the Iservice Tool Question
When I press the OFF button, the UPS just goes to the STANDBY mode and the fan continues spinning producing much noise. The manual states that there should be the SHUTDOWN mode. So, how to shut it down completely without disconnecting it from the mains?
Answer
It can only be switched to bypass or standby, and then the mains input is disconnected to completely shut down. Question
Each button pressing produces a loud beep. How to turn that beeping off?
Answer
Disconnect the mains input and switch the machine to battery mode. Then press and hold the first and third keys in battery mode for more than 1 second Question
Is it possible to make the UPS to shutdown when it has no load (so, when the only desktop connected to it is turned off)?
Answer
There is no such function for the time being